Home |
|
|||||||||||||||||||||||
|
Description: For faster results, reduce C2. Don't use less than 1.5k on R1 and R2. R2 controls the OFF time which is 0.4-0.25=0.15 seconds, so that R2=2.2K ohms. R1 controls the ON time. PARTS LIST: U1 ------ LM555 MONOSTABLE TIMER Q1 ------ 100V 28A 0.0429ohm POWER MOSFET Package D2PAK 2, 1, 3 L1 ------ SOLENOID 3 OHM WATER MIST SPRAYER SOLENOID S1 --------- SWITCH TOGGLE SPDT R1 ------ RESISTOR 1.5K 1/4watt rating R2 ------ RESISTOR 2.2K 1/4watt rating R3 ------ RESISTOR 1K 1/4watt rating C1 ------- 0.1uF C2-------- 100uF 16WVDC C3 ------- 10uF D1 -------- 1N4001 RECTIFIER DIODE D2 -------- 1N914A DIODE
|
|
||||||||||||||||||||||
|
||
updated 12-16-00 |